Vent heating elements are used in areas with modern home ventilation technology
and provide incoming air re-heaters directly at the inflow opening of the respective room.
Within an HRV system, they assume the remaining heat needs for the
entire heat output during the cold periods - with individual room control.
They are used in simple ventilation systems to avoid cold air drafts.
i
i
i
i
i
i
i
i
Connection housing
Heating element attachment with
disc attachment
Heating element attachment with butterfly attachment
Heating element attachment with 45° slot bezel attachment
Heating element attachment with slot bezel attachment
The connection housing is for connection air lines and the power supply
as well as for the inclusion of the heating element housing.
The element is attached using screws.
Multipoint connector for connection to the
power supply
i
The vent heating element with disc attachment and an
air outlet angle of 360° is used for installation in the ceiling.
By completely pushing the heating element into the connection housing a connection
to the voltage supply is created.
Contact protection screen
i
Screw (3x) for continuous setting of the air outlet opening
i
Screw (2x) for mounting in the connection housing
i
PTC Register
i
Circuit board with overload protection, flow and temperature cutoff
i
A butterfly attachment is used for wall mounting of the classic vent heating attachment.
A relatively large air velocity can be attained through restriction of the outlet slot.
By completely pushing the heating element into the connection housing a connection
to the power supply is created.
Contact protection screen
i
Continuous setting of the restriction in an installed condition
i
Screw (2x) for mounting in the connection housing
i
PTC Register
i
Circuit board with overload protection, flow and temperature cutoff
i
The vent heating element classic with the slot bezel attachment is used for wall installation.
A relatively large air velocity can be attained through restriction of the outlet slot.
By completely pushing the heating element into the connection housing a connection
to the power supply is created.
Contact protection screen
i
Screw (2x) for mounting in the connection housing
i
PTC Register
i
Circuit board with overload protection, flow and temperature cutoff
i
The vent heating element classic with its 45° slot bezel attachment is used for wall installation in high rooms.
A relatively large air velocity can be attained
by the cross-sectional narrowing of the outlet slot, which is aligned 45° downwards.
By completely pushing the heating element into the connection housing a connection
to the power supply is created.
Contact protection screen
i
Screw (2x) for mounting in the connection housing
i
PTC Register
i
Circuit board with overload protection, flow and temperature cutoff
i
Connection housing
Heating element attachment with disc attachment
Heating element attachment with butterfly attachment
Heating element attachment with slot bezel attachment
Heating element attachment with slot bezel attachment 45°
classic
6x3CT130-V TV
article no. 70117
●
●
Series Type
classic
6x3CT130-V BV
article no. 70123
●
●
classic
6x3CT130-V SV
article no. 70124
●
●
classic
6x3CT130-V SV45
article no. 70281
●
●
Series Type
Unit
classic
6x3CT130-V TV
article no. 70117
classic
6x3CT130-V BV
article no. 70123
classic
6x3CT130-V SV
article no. 70124
classic
6x3CT130-V SV45
article no. 70281
Type of installation
Installation diameter / Diameter
air connection
Installation depth
Mounting
Volume flow (recommended)
Performance (TE20°C)
Performance (TE 30°C)
Pressure loss
mm
mm
m³/h
W
W
Pa
Ceiling
130
46
Screws
10 … 40
140 … 520
130 … 455
5 … 14
Wall
130
46
Screws
10 … 40
140 … 520
130 … 455
15 … 37
Wall
130
46
Screws
10 … 40
140 … 520
130 … 455
14 … 33
Wall
130
46
Screws
10 … 40
140 … 520
130 … 455
16 … 39
Flat duct connection casing FKAG (article no. 70167)
Connection option for flat duct 200x40mm
i
Cable feed incl. tension relief and internal connection clamps
i
Plugs for unused flat duct connection 150x40mm / 200x40mm
i
Immersion pipe sliding sleeve TSH (article no. 70170)
Continuous length adaptation (270 … 365mm)
i
Cable feed 2-times (for parallel switching of other vent heating elements) incl. tension relief and internal connection clamps
i
Mounting for connection housing
i
Connection option for flat duct 150x40mm
i
Mounting for connection housing
Alternative: Mounting for immersion pipe sliding sleeve
i
Mounting for flat duct housing
i
Lip seal Seal between immersion pipe and sliding sleeve
i
+49 (0) 2764 261 35 - 0
+49 (0) 2764 261 35 - 20