Vent heating elements are used in areas with modern home ventilation technology employing heat recycling and provide incoming air re-heating directly at the inflow opening of the respective room.
Within an HRV system, they assume the remaining heat needs for the
entire heat output during the cold periods - with individual room control.
They are used in simple ventilation systems to avoid cold air drafts.
i
i
Connection housing
Outer collar
Air velocity attachment
Heating element attachment
Disc attachment
Annular gap restrictor
The connection housing is for the connection of air lines and the power supply as well as for accommodating the heating element attachment. The electrical cable line lies outside the air pipe.
It is attached in a 125mm air pipe using tension wedges.
Multipoint connector for connection to the power supply incl. cover
i
Screws (3x) for using the tension grips
i
Straight edges with groove marks for alignment
i
Cutting mark for cutting off the connection pipe
i
Tension grip in park position
Tension grip in clamped position
i
Lip seal
i
The outer collar assumes the airflow together with the disc vent attachment and the
characteristic bezel with disc vent - alternatively with air velocity attachment.
The outer collar makes flush installation possible on the attachment level
or a shadow joint setting.
Graduation for setting the shadow joint
Shadow joint
(0.0 mm / 0.5 mm /
1.0 mm / 2.0 mm)
i
Contact protection screen
i
By completely pushing the heating element into the connection housing a connection to the power supply is created.
Function display
i
Screw (2x) for mounting in the connection housing
i
PTC Register
i
Circuit board with bridge for power adjustment, overload protection, flow and temperature cutoff
i
Openings, plugs for controlled bypass
i
Temperature switch (option)
i
The disc vent attachment with an air outlet angle of 360° is used for ceiling mounting. The disc attachment has lock positions through which the air outlet gap can be set in 1mm graduations.
Hollow back for mounting on heating element attachment (5 lock positions)
Reproducible setting through the use of graduated grooves
i
Window for reading the
setting positions
i
Preset breaking point B-B for reducing the RSB by 30°
i
Preset breaking point A-A for reducing the RSB by 30°
i
In the case of wall mounting of the vent heating element, the velocity attachment with a slot bezel is used. A relatively large air velocity can be attained through restriction of the outlet slot.
Locking groove in heating element attachment
i
Connection housing
Outer collar
Heating element attachment
Annular gap restrictor
Disc attachment
Air velocity attachment
eVA 125
5x3CT130-U TV
article no. 70273
●
●
●
●
●
eVA 125
5x3CT130-U WV
article no. 70274
●
●
●
●
Series Type
Series Type
Unit
eVA 125
5x3CT130-U TV
article no. 70273
eVA 125
5x3CT130-U WV
article no. 70274
Type of installation
Installation diameter / Diameter air connection
Installation depth
Mounting / Fixing
Volume flow (max.)
Performance
Volume flow
Performance zone 1…5 (TE 20°C)
Performance zone 1, 2 and 5 (TE 20°C)
Performance zone 1…5 (TE 30°C)
Performance zone 1, 2 and 5 (TE 30°C)
Pressure loss
mm
mm
m³/h
m³/h
W
W
W
W
Pa
Ceiling
125
47,5
Traction claw (3x)
60
15 … 35
238 … 339
132 … 170
223 … 307
123 … 155
7 … 30
Wall
125
47,5
Traction claw (3x)
60
15 … 35
238 … 339
132 … 170
223 … 307
123 … 155
7 … 30
+49 (0) 2764 261 35 - 0